| IEEE802.3, 802.3u, 802.3x, 802.1D,
802.1W, 802.1Q, 802.1p, 802.1X, 802.3ad,
802.3z |
|
|
|
|
| IGMP V1/V2/V3 device, GMRP, GVRP,
SNMP V1/V2c/V3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP,
RARP, RMON |
|
|
|
|
| MIB-II, Ethernet-Like MIB, P-BRIDGE
MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3,
9 |
|
|
|
|
| IEEE802.3x flow control, back
pressure flow control
Interface |
|
|
|
|
| |
|
|
|
|
| 10/100BaseT(X) or
10/100/1000BaseT(X) auto negotiation
speed |
|
|
|
|
100BaseFX(SC/ST connector), and
optional 1000BaseSX/LX/LHX/ZX (LC
connector) |
|
|
|
|
|
|
|
| PWR1, PWR2, FAULT, 10/100M (TP
port), 100M (Fiber port), MASTER,
COUPLER |
|
|
|
|
| Two relay outputs with current
carrying capacity of 1A @ 24
VDC |
|
|
|
|
|
Two inputs with the same ground, but
electrically isolated from the electronics
+13 to +30V for state “1”
-30 to +3V for state “0”
Max. input current: 8
mA
|
|
|
|
|
| |
|
|
|
|
Multi mode: 0 to 5 km, 1300 nm
(50/125 μm, 800 MHz*km) 0 to 4 km, 1300 nm (62.5/125 μm, 500
MHz*km) Single mode: 0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km)) 0
to 80 km, 1550 nm (9/125 μm, 19
PS/(nm*km)) |
|
|
|
|
|
Multi mode: -20 dBm Single mode: 0 to 40 km, -5 dBm 0 to 80 km,
-5 dBm
|
|
|
|
|
Multi mode: -14 dBm Single
mode: 0 to 40 km, 0 dBm 0 to 80 km, 0
dBm |
|
|
|
|
Single mode: -36 to -32 dBm
Multi mode: -34 to -30
dBm |
|
|
|
|
| |
| Optical Fiber |
| 1000BaseSX/LX/LHX/ZX |
|
|
|
Multi mode:
1000BaseSX 0 to 500 m, 850 nm (50/125 μm, 400 MHz*km) 0 to 275 m, 850
nm (62.5/125 μm, 200 MHz*km)
1000BaseLX 0 to 1100 m, 1310 nm (50/125 μm, 800 MHz*km) 0 to 550 m,
1310 nm (62.5.125 μm, 500 MHz*km) Single mode:
1000BaseLX 0 to 10 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km))
1000BaseLHX 0 to 40 km, 1310 nm ((9/125 μm, 3.5 PS/(nm*km)))1000BaseZX 0 to 80 km, 1550 nm ((9/125 μm, 19 PS/(nm*km))
|
|
|
|
|
| SFP-1GSXLC: |
-9.5 dBm |
| SFP-1GLXLC: |
-9.5 dBm |
| SFP-1GLHXLC: |
-4 dBm |
|
SFP-1GZXLC:
|
0
dBm |
|
|
|
|
| SFP-1GSXLC: |
-4 dBm |
| SFP-1GLXLC: |
-3 dBm |
| SFP-1GLHXLC: |
+1 dBm |
|
SFP-1GZXLC:
|
+5
dBm |
|
|
|
|
| SFP-1GSXLC: |
0 to -18 dBm |
| SFP-1GLXLC: |
-3 to -20 dBm |
| SFP-1GLHXLC: |
-3 to -24 dBm |
|
SFP-1GZXLC:
|
-3 to -24
dBm |
|
|
|
|
|
|
|
|
| 24 VDC (12 to 45 VDC), redundant
dual inputs |
|
|
|
|
0.67A (EDS-518A), 0.78A
(EDS-518A-MM,
EDS-518A-SS) |
|
|
|
|
| Two removable 6-pin terminal
blocks |
|
|
| Overload Current
Protection |
|
|
| Reverse Polarity
Protection |
|
|
|
|
| |
|
|
|
|
|
|
|
95 x 135 x 140 mm (W x H x
D) 3.74 x 5.31 x 5.51 in. (W x H x D)
|
|
|
|
|
|
|
|
| DIN-Rail, Wall Mounting (optional
kit) |
|
|
|
|
| |
|
|
|
|
0 to 60°C (32 to 140°F) -40 to
75°C (-40 to 167°F) for T
models |
|
|
|
|
| -40 to 85°C (-40 to
185°F) |
|
|
| Ambient Relative
Humidity |
|
| 5% to 95%
(non-condensing) |
|
|
|
|
| |
|
|
|
|
| UL508, UL60950, CSA C22.2 No.
60950-1, EN60950-1 |
|
|
|
|
UL/cUL Class I, Division 2, Groups
A, B, C and D ATEX Class I, Zone 2, EEx nC IIC
(Pending) |
|
|
|
|
|
|
|
| FCC Part 15, CISPR (EN55022) class
A |
|
|
|
|
EN61000-4-2 (ESD), level
3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 2 EN61000-4-5
(Surge), level 3 EN61000-4-6 (CS), level
3 EN61000-4-8 EN61000-4-11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
240,000 hrs Database: Telcordia
(Bellcore), GB |
|
|
|
|
|
|
|